Installation – Desa LMFP33NR(A) User Manual

Page 15

Advertising
background image

www.desatech.com

111604-01K

15

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not pro-

vided)

1. Remove two screws that hold fireplace screen

in place for shipping. These screws are located

near top of screen. Discard screws. Lift fire-

place screen up and pull out to remove.

2. Open lower louver door. Carefully pull

straight out on the wire harnesses attached to

right side and front of remote receiver module

(see Figure 21).

3. Remove screws that attach log base assembly

to fireplace (see Figure 21). Carefully lift up

log base assembly and remove from fireplace

(see Figure 21).

Note:

If adding the G8000A series brick liner

accessory, install it now. Follow instructions in

G8000A accessory kit.

CAUTION: Do not pick up

log base assembly by burner.

This could damage burner. Only

handle base by grates.

4. Route gas line (provided by installer) from

equipment shutoff valve to fireplace. Route

flexible gas supply line through one of the

access holes.

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 22).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

5. Attach the flexible gas line to gas supply (see

Figure 22). Check tightness of flexible gas

line attached to gas regulator of fireplace (see

Figure 22).

6. Check all gas connections for leaks. See

Checking Gas Connections, page 16.

INSTALLATION

Continued

7. Replace log base assembly back into fireplace.

Feed flexible gas line into fireplace base area

while replacing log base assembly. Make sure

the entire flexible gas line is in fireplace base

area. Reattach log base assembly to fireplace

with screws removed in step 2.

Figure 21 - Removing Log Base

Assembly From Fireplace

O
F

F

P

ILO

T

O

N

Figure 22 - Attaching Flexible Gas Lines

Together

Flexible Gas Line from
Fireplace Gas Regulator

To Fireplace Gas
Regulator

Equipment Shutoff
Valve Provided by
Installer

Unplug From
Remote Receiver
Module

Log Base
Assembly

Screw

Screw

Propane/LP
To External Regulator
Natural Gas
To Gas Meter

Remote
Receiver
Module

Flexible Gas
Line

Advertising