Operating heater – Desa LMFP33NR(A) User Manual

Page 21

Advertising
background image

www.desatech.com

111604-01K

21

1. STOP! Read the safety information on

page 20.

2. Make sure equipment shutoff valve is fully

open.

3. Set remote selector switch in the AUTO

position (see Figure 35).

4. Press in and turn control knob clockwise

to the OFF position (see Figure 35).

5. Wait five (5) minutes to clear out any gas.

Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the

safety information on page 20. If you donʼt

smell gas, go to the next step.

6. Press in and turn control knob counter-

clockwise

to the PILOT position.

Press in control knob for five (5) seconds

(see Figure 35).

Note:

You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

7. With control knob pressed in, press and

release ignitor button. This will light pilot.

The pilot is attached to the rear of the front

burner. If needed, keep pressing ignitor

button until pilot lights.

Note:

If pilot does not stay lit, contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

8. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop out when

released, contact a qualified service person

or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 4

through 8.

AUTO MAN

Control Knob

Ignitor Button

Figure 35 - Remote Selector Switch,

Control Knob and Ignitor Button

Remote Selector
Switch

OPERATING HEATER

Continued

Figure 36 - Pilot (Propane/LP)

Ignitor
Electrode

Pilot Burner

Figure 37 - Pilot (Natural)

Ignitor
Electrode

Pilot Burner

9. Slightly push in and turn control knob coun-

terclockwise

to the ON position.

10. Press the on/off key on the remote control

to turn on appliance main burner. Wait at

least 5 seconds before setting desired flame

height.

11. Press the up or down key until the small

triangle is to the left of large flame icon

at the top of LCD display (see Figure 38,

page 22). Press the left or right key to set

the desired flame height.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Press on/off key on remote control and turn

control knob clockwise

to the OFF posi-

tion (see Figure 35).
Shutting Off Burners Only (pilot stays lit)

Press the on/off key on remote control or turn

control knob clockwise

to the PILOT

position.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 7 under Lighting

Instructions

, column 1.

2. Depress control knob and light pilot with

match.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow steps 9 through

11 under Lighting Instructions.

Advertising