Installation – Desa LMFP33NR(A) User Manual

Page 9

Advertising
background image

www.desatech.com

111604-01K

9

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Bottom

Right Sides

and Rear

42"

16"

0"

Figure 5 - Installing Hood to Firebox

Figure 6 - Assembling Trim

Side Trim

Slot

Mitered
Edge

Slot

Shim

Set Screws

Adjusting
Plate

Trim
Hanging
Screws

Assembled
Trim

Hanging
Notches
on Trim

INSTALLING HOOD

Install hood to top of firebox as shown in Figure

5. Use 3 Phillips screws provided

Top Trim

INSTALLATION

Continued

Figure 7 - Attaching Trim to Fireplace

*

Example

Figure 8 - Minimum Clearance for

Combustible to Wall

*Minimum 16 inches from Side Wall

ASSEMBLING AND ATTACHING
OPTIONAL TRIM
(Included with Mantel Accessory)

IMPORTANT:

If you are recessing the firebox in a

wall, do not attach trim at this time. See page 11.
Note:

The instructions below show assembling

and attaching trim to fireplace.

1. Remove packaging from three pieces of trim.

2. Locate four brass screws, two adjusting plates

with set screws and two shims in the hardware

packet.

3. Align shim under adjusting plate as shown in

Figure 6.

4. Slide one end of adjusting plate/shim in slot

on mitered edge of top trim (see Figure 6).

5. Slide other end of adjusting plate/shim in slot

on mitered edge of side trim (see Figure 6).

6. While firmly holding edges of trim together,

tighten both set screws on the adjusting plate

with slotted screwdriver.

7. Repeat steps 1 through 6 for other side.

8. Tighten trim hanging screws (#10 x 6.25

shoulder) into holes in cabinets. Place the

assembled trim onto fireplace cabinet. Align

hanging notches on trim with hanging screws

on side of fireplace (see Figure 7). Push trim

firmly into place, sliding hanging notches over

hanging screws.

INSTALLATION CLEARANCES

WARNING: Maintain the

minimum clearances. If you can,

provide greater clearances from

floor, ceiling and adjoining wall.

Carefully follow the instructions below. This will

ensure safe installation.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 8.

Example:

The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 8).

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 42 inches.

Advertising