5.2.

Operation

5.2.1. Power consumption and power loss

The power required from the mains supply and the waste heat
produced by the amplifiers power loss vary depending on the load
impedance and the signal levels and characteristics (e.g. speech, music).

In practice, the theoretical peak power consumption of a system will
only be sustained for a short period of time. Basing mains current and
air conditioning plant requirements on the peak power consumption of
the sound system would result in a generously over-specified
installation. The key factor in power consumption calculations is the crest
factor (CF) of the music or speech signal - the ratio of peak to
sustainable RMS voltage of the signal.

A crest factor of 2.4 represents 1/3 of the maximum sine output power
and it can be seen as the worst case signal that can be accessed in real
world conditions. A proper power distribution should be able to handle
the current ratings given in the table below referring to CF 2.4. Using
the D6 temporarily with well known signals of higher crest factor, the
power distribution can be downsized within the range given in the table.

The table gives power figures for various types of signal waveforms.
They were measured on a D6 driving a 4 ohm load (both channels) to
the clipping point of both channels using a sine wave burst signal of
24 dBu with a variable duty cycle. The mains power supply used for the
measurements supplied an ideal sine wave with 230 V/50 – 60 Hz at
an internal resistance of 0.5 ohms (0.12/0.1 ohms for 115/100 V)
equivalent to a mains lead of 20 m (65.6 ft) with a cross section of
1.5 mm

2

(6 mm

2

/ 8 mm

2

for 115/100 V).

Signal
waveform

CF

Duty

P

out

[W]

P

in

[W]

P

loss

[W]

I

in

[A]

U

in

[V]

BTU/hr

kCal/hr

Sinus

1.4

1/1

1200

1560

1645

1715

360

445

515

6.8

14.3

17.2

230

1228

310

115

1518

383

100

1757

443

Highly compressed
music*

2.4

1/3

400

520

550

570

120

150

170

2.3

4.8

5.7

230

410

103

115

512

129

100

580

146

Music with low
dynamic range

4.0

1/8

150

215

220

220

65

70

70

1.0

2.0

2.2

230

222

56

115

239

60

100

239

60

Tab. 4: D6 Power balance

Key:
CF:
Crest factor, Duty: Duty cycle, P

out

[W]: Max. average output power (sum of both channels), P

in

[W]: Input power (effective power)

P

loss

: Power loss (thermal power), I

in

[A]: Resulting current, U

in

[V]: Mains voltage

* Maximum practicable operation