Installation – Desa VML27PR User Manual

Page 12

Advertising
background image

www.desatech.com

111115-01F

1

inStALLAtion

Continued

FLOOR CLEARANCES

A. If installing appliance on the floor level, you

must maintain the minimum distance of 14"

to combustibles (see Figure 8).

B. If combustible materials are less than 14" to

the fireplace, you must install appliance at

least 5" above the combustible flooring (see

Figure 9).

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

14"

Min.

Combustible

Material

Noncombustible Material

Hearth

5"

Min.

Combustible

Material

Area of Various Standard

Round Flues

Diameter

Area

5"

0 sq. inches

6"

9 sq. inches

"

39 sq. inches

8"

51 sq. inches

Chimney

Minimum permanent

Height

Flue Opening

6' to 15'

39 sq. inches

15' to 30'

9 sq. es

Figure 10 - Attaching Damper Clamp

Damper
Clamp

Damper

Manufactured

Fireplace

Masonry Fireplace

Damper

Damper

INSTALLING DAMpER CLAMp
ACCESSORY FOR VENTED
OpERATION

Note:

When used as a vented heater, appliance

must be installed only in a solid-fuel burning

fireplace with a working flue and constructed of

noncombustible material.

If your heater is a manually controlled model, you

may use this heater as a vented product. There

are three reasons for operating your heater in the

vented mode:

1. The fireplace does not meet the clearance

to combustibles requirements for vent-free

operation

2. State or local codes do not permit vent-free

operation

3. You prefer vented operation

If reasons number 1 or 2 above apply to you, you

must permanently open chimney flue damper. You

must install the damper clamp accessory (to order,

see Accessories, page 29). This will insure vented

operation (see Figure 10). The damper clamp will

keep damper open. Installation instructions are

included with clamp accessory.

See chart below for minimum permanent flue

opening you must provide. Attach damper clamp

so the minimum permanent flue opening will be

maintained at all times.