Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

2" from where the pilot flame comes out of the

pilot assembly (see Figure 36). With the unit off,

lightly blow air through the air inlet hole. You may

blow through a drinking straw if compressed air

is not available.

CLEAning And

MAintEnAnCE

Continued

Thermopile

Jumper Wire

Figure 36 - Pilot Inlet Air Hole

Burner Tube

Pilot Assembly

Pilot Air
Inlet Hole

Ports/Slots

LOGS

• If you remove logs for cleaning, refer to Install-

ing Logs, page 17, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

WiRing diAgRAM

SPECiFiCAtionS

Natural Gas Propane/LP

Btu (Variable)

26,000/39,000 26,000/39,000

Type Gas

Natural Gas Propane/LP

Ignition

Piezo

Piezo

Pressure Manifold 3.5" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

Maximum

10.5"

14"

Minimum*

5"

11"

Shipping Weight 32 lbs.

32 lbs.

* For input adjustment

REPLACEMEnt PARtS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

pARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they can’t supply original replacement part(s),

call DESA Heating Products’ Technical Service

Department at 1-866-672-6040.

When calling DESA Heating Products, have

ready

• your name

• your address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the

factory.

pARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

can’t supply original replacement part(s), call

DESA Heating Products at 1-866-672-6040 for

referral information.

When calling DESA Heating Products, have

ready

• model number of your heater

• the replacement part number

SERViCE HintS

When Gas pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, con-

tact your local propane/LP or natural gas supplier.

tECHniCAL SERViCE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Products’ Technical Service Department

at 1-866-672-6040. When calling please have your

model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ techni-

cal services web site at www.desatech.com.

Advertising