Troubleshooting – Desa VML27PR User Manual

Page 26

Advertising
background image

www.desatech.com

111115-01F

6

tRouBLESHooting

Continued

OBSERVED PROBLEM

ODS/pilot lights but flame

goes out when control knob is

released

Burner does not light after ODS/

pilot is lit

Delayed ignition burner

Burner backfiring during com-

bustion

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Fully open equipment shutoff

valve

4. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 23) or replace ODS/pilot

assembly

5. Hand tighten until snug, then

tighten 1/4 turn more

6. Replace pilot assembly

7. Replace control valve

1. Clean burner (see Cleaning

and Maintenance, page 23) or

replace burner orifice

2. Contact local natural or pro-

pane/LP gas company

3. Reconnect leads (see Wiring

Diagram, page 24)

4. Replace battery in transmitter

and receiver

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 23) or

replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 23) or

replace burner orifice

2. Replace damaged burner

3. Replace gas control

POSSIBLE CAUSE

1. Control knob not fully pressed in

2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Pilot flame not touching

thermocouple, which allows

thermocouple to cool, caus-

ing pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

5. Thermocouple connection

loose at control valve

6. Thermocouple damaged

7. Control valve damaged

1. Burner orifice clogged

2. Inlet gas pressure is too low

3. Thermopile leads disconnect-

ed or improperly connected

4. Burners will not come on in

remote position

1. Manifold pressure is too low

2. Burner orifice clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

Advertising