4 noise from fans and rattling, Figure 18a, Figure – Doremi DCP-2000 User Manual

Page 18

Advertising
background image

(a)

(b)

Figure 18: 2U Fan Shock Mounts Visual Inspection – Correct Installation

Caution: Do NOT take out the fans from the shock mounts. Do a visual inspection only.

If the shock mounts are not properly attached, use your fingers to fix them as illustrated below:

Figure 19: 2U Fan Shock Mounts Re-Attachment Example

If the shock mounts need to be replaced, please contact Doremi (Section 1.2) for additional guidance.

5.1.4 Noise from Fans and Rattling

In a secure location, power on the unit with the lid off.

Listen to see if there is any noise coming from fans.

If such noise is coming from a fan, remove power to fan by unplugging the noisy fan connector. When
the connector corresponding to the noisy fan is removed, the noise should stop.

Then replace that fan with a fan having the same Part Number. Contact your local Doremi Support
team (Section 1.2) for fan replacement and for additional guidance.

D2K.DP.000255.DRM

Page 18 of 24

Version 1.8