Doremi DCP-2000 User Manual

Page 8

Advertising
background image

2 Digital Cinema Server Recommended Operating

Conditions

Listed below are the recommended operation conditions for Doremi digital cinema servers:

1. AC power to the unit should be feed through UPS, greater than or equal to

600VA per player,

which provides a logical signal that shows the power failure.

2. To properly shutdown the server, do the following:

Go to Menu/Logout and click on Logout.

Click on the Shutdown button.

3. Ensure that AC ground lines are CE/UL rated (for ohm resistance) for the server & projector

power connections.

4. Ground voltage difference from cinema player to projector should not exceed 1Vac/dc to

minimize ground current circulations through dual link HD-SDI lines (measurement done
between both chassis grounds with dual link & AES disconnected).

5. Ground voltage difference from cinema player to audio processor should not exceed 1Vac-dc

to minimize ground current circulations through AES/EBU lines (measurement done between
both chassis grounds with dual link & AES disconnected).

6. Installation of the cinema player in a typical protected rack enclosure to avoid physical shocks

and vibrations during player/disk operation.

7. Ambient air temperature at front and rear of cinema player should not exceed 35°C (95°F)

when operating unit.

8. Operating ambient humidity should be between 10% and 85% Non-Condensing.

D2K.DP.000255.DRM