Ml - heavy duty lift mechanism – Future Automation ML User Manual

Page 17

Advertising
background image

In

st

all

at

io

n

: R

23

2 C

on

tro

l

Page 16 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

ML - Heavy Duty Lift Mechanism

Operation Details

DC1
Low voltage power output for
motor drive.LED’s to show
operation of limit switches
and positional counters

Mains Voltage Input

IR LED

IR Input Jack

RS232

Contact Closure























SLQV

RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232

Details
Baud rate: 9600
Stop bit:

1

Parity:

None

Databits:

8

Pin 1: RX

Pin 6 : TX

Pin 3 & 4: GROUND

Pin 2: TX

Pin 3: RX

Pin 5: GROUND

IMPORTANT
Ensure protocol is entered exactly as written,
including Carriage Return (Enter / ASCII 13).

RJ25

9 PIN D

PIN 1: RX

TO

PIN 2: TX

PIN 6: TX

TO

PIN 3: RX

PIN 3: GROUND

TO

PIN 5: GROUND

PIN 4: GROUND

TO

PIN 5: GROUND

Protocol

Action

fa_in Carriage Return (Enter )

Device IN

fa_out Carriage Return (Enter )

Device OUT

fa_stop Carriage Return (Enter )

Device STOP (At any position)

Advertising
This manual is related to the following products:

MLI, PL, PLI, HL