5.

TEST Key:

Press this key in the TDR mode and measure a distance to a cable fault

6.

VOP Key:

Toggle the VOP Key to select from the preprogrammed VOP values for
different cable types.

7.

MODE Key :

This key allows the user to select measurement & setup modes:

7.1 Push the MODE Key to select REC mode :

Measure 5 carrier signal levels from the Dark Transmitter.

7.2 Push the MODE Key again to select CABLE ID mode :

Tags an ID number to a cable that matches the resistor value terminated

at the cable end or displays OPEN or SHORT if either condition exists.

7.3 Push the MODE Key again to select TDR mode :

Measures distance to a cable fault (open/short), using TDR technology

7.4 Push the MODE key again to select Auto Shutdown Mode and then

select the inactivity period before the meter automatically shuts down.


8.

CAL Key :

This key activates 2 functions:

8.1 Press the CAL Key in REC mode :

This is to store the input signal level as a calibrating reference level.

8.2 Press the CAL Key in TDR mode :

This is to store the VOP value calculated from a 20 ft cable as a
calibrating reference VOP value.

9.

PC Key :

Press to download saved signal level data via the RS232 port to a PC

10/11. / Keys :

Use to select memory stations