2.1 Measuring Insertion Loss:

The Insertion Loss or the Attenuation of the cable under test (CUT) can be
measured as follows:

2.1.1 Connect the transmitter directly to the input of the receiver. Use a high

quality splice or a jumper cable that is no more than 12 inches between
transmitter and receiver for this step. NOTE: Normally the transmitter

output levels do not require adjustment before performing this step unless

the operator is experiencing erratic operation or measurements


2.1.2 Press the CAL Key to initiate a calibration operation. The receiver will store

the measured signal levels of each carrier and use them as reference

levels. The LCD display will appear as shown below.





2.1.3 The display will then show all five bars fully illuminated across the screen

and –0db noted for each frequency. If -0db is not displayed for each

value then try adjusting the carrier level potentiometer on the transmitter

for the frequency in question and repeat the calibration procedure.

2.1.4 Disconnect the transmitter from the receiver and connect the transmitter

to one side of the CUT and the receiver to the other side. The receiver will

display the attenuation values of the CUT. The LCD should look similar to

the following :