Installation

8

Ilumipod 18g2 IP Optic RGB User Manual (Rev. 2)


The Ilumipod
18g2 IP Optic
RGB must be

linked using DMX cable in
a daisy chain (serial)
fashion. To comply with
the EIA-485 standard, no
more than 32 products
should be connected on
one daisy chain without
using a DMX optically
isolated splitter. Doing
otherwise may result in
deterioration of the digital
DMX signal.

USITT
recommends
limiting the total

length of the DMX cable
(from the first
product/controller to the
last product) to 300~455
m (985~1,500 ft).

Disconnect the
product from the
AC power before

opening it.

The signal cable
must match or
exceed the

electrical characteristics
of the Belden® 9841
cable for EIA RS-485
applications. You may
also use CAT5, 5e, or
CAT6 LAN cable.

DMX Linking

You may link the Ilumipod 18g2 IP Optic RGB to a DMX controller using a standard DMX
serial connection. If using other DMX products compatible with the Ilumipod 18g2 IP Optic
RGB, you can control each individually with a single DMX controller.

If you are not familiar with the DMX standard, or if you need information about the DMX cables
needed to link the Ilumipod 18g2 IP Optic RGB to a DMX controller, you may download the
“DMX Primer” from the ILUMINARC® website at

http://www.iluminarc.com/reports/dmx-

primer

.

DMX Modes

The Ilumipod 18g2 IP Optic RGB uses the standard DMX data connection for its all its
DMX personalities. Refer to the

Introduction

chapter for a brief description of these

modes. Refer to the

Operation

chapter to learn how to configure the Ilumipod 18g2 IP

Optic RGB to work in these modes. The

DMX Values

section provides detailed

information regarding the DMX modes.

DMX Mode

DMX Address

ARC FULL

506

ARC1

510

ARC1+D

509

SOLID

512

Signal Wiring

To provide signal for the Ilumipod 18g2 IP Optic RGB, you can connect the bare-ended,
IP67-rated signal cable from the product to two IP67-rated signal connectors (DMX
In/DMX Out) or use an IP67-rated junction box. In this case, make sure to use
IP67-rated conduit.

Protocol Connectivity

The Ilumipod 18g2 IP Optic RGB uses USITT DMX 512 protocol. The procedure
below illustrates the recommended connection method.





















Advertising