Spot-1i callouts - internal power supply, Spot-1 callouts - internal power supply, Spot-1 i callouts - internal power supply – Oxmoor SPOT-1 User Manual

Page 4

Advertising
background image

Figure 1.0: SPOT-1i Infrared Emitter With Internal Power Supply

Page 2

SPOT-1

i CALLOUTS - INTERNAL POWER SUPPLY

1. HOUSING

– Die-stamped, 20 gauge, cold rolled steel

with white powder coat finish.

2. RF CONDUIT KNOCKOUT

– 1/2” uniform opening for RF

cable entry. NOTE: requires a gasketed EMT air tight com-
pression connector or gland nut when used in a plenum
ceiling.

3. PLASTER FRAME

– Housing adjusts in plaster frame

1-3/8” to accommodate different ceiling thicknesses.

4. BAR HANGERS

– Fully adjustable “nail-less” bar hang-

ers fit between 24” joists and span 24” T-bars. Hanger bars
are scored for reducing for 12” joist spans. Housing may
be positioned at any point along length of fully extended
bar hangers.

5. TRIM RING

– White metal trim ring with glass lens.

6. BRACKET PLATE

– Ridge plate adjusts and locks with-

out tools. Used to support the internal power supply on
the SPOT-1i PS version.

11

5

3

2

1

4

6

7

9

10

7. RF INPUT CONNECTOR

– BNC-style RF input connec-

tor. Input impedance 25 k ohms at 95 kHz.

8. DC POWER SUPPLY

– 24V DC supply at 1.25 amps, volt-

age regulation

±

5 % with a maximum ripple P-P of 240

mV. Accepts 100 - 230V AC connection through junction
box.

9. DC POWER CONNECTION

– 3-pin header connector. Cen-

ter Pin Positive with both outside pins negative.

10. DIODE ARRAY

– 72-diode array designed to cover small

“spot” areas of approximately 314 to 2,800 square feet.

11. JUNCTION BOX

– Fully gasketed for Plenum listing. UL

listed for through branch circuit wiring.

12. POWER KNOCKOUTS

– Positioned to accommodate

straight conduit runs. All conduit knockouts are uniform
1/2” size with pry out slots.

13. CONDUIT FITTINGS

– Plenum-approved flexible metal-

lic tubing and gasketed connectors.