Spot-1 connections, External, Spot-1i with internal power supply – Oxmoor SPOT-1 User Manual

Page 7: Rf connection for in-line spot-1, Spot-1e with, Power supply, Rf connection for end of line spot-1

Advertising
background image

Page 5

SPOT-1 CONNECTIONS

SPOT-1i WITH INTERNAL POWER SUPPLY

(Refer to Figure 3.0)

The internal supply requires 100 - 230V AC at 30 watts
maximum. Connect the AC wiring to SPOT-1 through the
JUNCTION BOX as shown, using 1/2” conduit terminated
into an EMT style steel gasketed connector.

Figure 3.1: DC Connection

RF CONNECTION FOR IN-LINE SPOT-1

(Refer to Figure 3.2)

A 1/2” cutout is provided for the RF cable entrance and
exit. The cutout can be used with 1/2” conduit terminated
into an EMT compression connector. If using Plenum cable,
termination can be made through a gasketed Gland Nut.

A splitter (T) is provided with each SPOT-1. The splitter
routes RF to the unit and then provides a means to route
the RF to the next inline unit.

24V DC, 1.25A

using class

2 wiring

1/2” Conduit

Figure 3.2: RF In Line Connection

EMT Compression, Steel Connector with Gasket

“Provided by Contractor”

Terminate the RF cable with a standard BNC style T Connector

Junction Box

SPOT-1e WITH

EXTERNAL

POWER SUPPLY

(Refer to Figure 3.1)

SPOT-1 Requires 24V DC at 1.25 amps, voltage regulation

±

5 % with a maximum peak to peak ripple of 240 mV.

Connect the external power supply to SPOT-1 through the
JUNCTION BOX as shown: Using 1/2” conduit terminated
into an EMT style steel gasketed connector.

Figure 3.0: 100 - 230V AC Connection

100-230V AC

using class

2 wiring

1/2” Conduit

EMT Compression Steel Connector with Gasket

“Provided by Contractor”

Junction Box

RF CONNECTION FOR END OF LINE SPOT-1

(Refer to Figure 3.3)

A 1/2” cutout is provided for the RF cable entrance. The
cutout can be used with 1/2” conduit terminated into an
EMT compression connector. If using Plenum cable, ter-
mination can be made through a gasketed gland nut.

Figure 3.3: RF End Of Line Connection

RF Cable from

modulator

RF Cable to next SPOT-1

RF Cable from

modulator

RF 50 ohm or 75 ohm terminator.

Determined by transmitter output impedance

EMT Compression,

Steel Connector with Gasket

“Provided by Contractor”

Terminate the RF cable with a standard BNC style T Connector

EMT Compression Steel Connector with Gasket

“Provided by Contractor”

Advertising