065-1800 series Hardened Media Converter

8

User’s Manual

Installation

This chapter gives step-by-step installation instructions for the Converter.

Selecting a Site for the Equipment

As with any electric device, you should place the equipment where it will not

be subjected to extreme temperatures, humidity, or electromagnetic
interference. Specifically, the site you select should meet the following
requirements:

The ambient temperature should be between -

40° to 165° Fahrenheit (-40° to +74°

Celsius).

The relative humidity should be less than 95 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC)

standards for IEC 801-3, Level 2 (3V/M) field strength.

Make sure that the equipment receives adequate ventilation. Do not block the

ventilation holes of the equipment.

The power outlet should be within 6 feet (1.8 meters) of the product.

DIN Rail Mounting

Fix the DIN rail attachment plate to the back panel of the media converter.

Installation: Place the media converter on the DIN rail from above using the

slot. Push the front of the media converter toward the mounting surface
until it audibly snaps into place.


Removal: Pull out the lower edge and then remove the media converter from

the DIN rail.