Network Config

The “network config” command allows for editing the network configuration settings. These settings begin
with the unit IP address, each octet is displayed allowing a new value to be entered, or just accepting the
current value by depressing the enter key. An entered IP value of 0.0.0.0 defines DHCP mode. Once the
IP address is entered, Gateway and Subnet masks may be entered or modified in the same manner.
Values entered are not permanently stored until the

“Save and Exit” command is executed.

Factory Defaults

The “Factory Defaults” command resets all setup values to their initial defaults.

DHCP mode = enabled

SMTP port = 25

TEKPATROL port = 5070

TEKCONTROL port = 5072

PASSCODE = 6373

Serial Port 1 = 9600,N,1

SerialPort2 = 9600,N,1

Save and Exit

The “Save and Exit” command forces a save of data to the TekMonitor non-volatile storage area. Once
saved, the unit is reset, disconnecting the USB channel. The TekDebug program will have to be
restarted in order to reestablish connection.

Reset

The “Reset” command forces a reset of the TekMonitor resulting in a disconnection of the USB channel.
The TekDebug program will have to be restarted in order to reestablish connection.

Quit

The “Quit” command disconnects the USB channel, and the TekDebug program will have to be restarted
in order to reestablish connection.