DefaultConformityTolerance
VPARAMETER
552
Default value for ConformityTolerance computed by the Locator by analyzing the calibration, the contour
detection parameters, and the search parameters. Read only.
Syntax
MicroV+
value = VPARAMETER (sequence_id, tool_id, 552, index_id, object_id)
V+
value = VPARAMETER ($ip, sequence_id, tool_id, 552, index_id, object_id)
Remarks
This default value is used for ConformityTolerance when UseDefaultConformityTolerance is set to True.
Type
Double
Range
Greater than 0.
Parameters
$ip
IP address of the vision server. Applies to V+ syntax only. Uses standard IP
address format, for example: 192.168.1.120.
sequence_id
Index of the vision sequence. The first sequence is 1.
tool_id
Index of the tool in the vision sequence. The first tool is 1.
ID
552: the value used to reference this property.
index_id
N/A
object_id
N/A
Related Properties
DefaultConformityTolerance