Datalogic Scanning DS8100A User Manual

Page 15

Advertising
background image

DS8100A QUICK GUIDE

15

Minimum Code Height for ACR Reading (mm)

45°

30°

Conveyor Speed (m/s)

0.5

1

1.5 2 2.5 3 0.5 1 1.5 2 2.5 3

0.25

7 9 10 12 13 15 6 6 8 9 10 11

0.30

8 9 11 12 14 15 6 7 8 9 10 12

0.33

9 10 11 13 14 16 6 7 8 9 11 12

0.38

10 11 12 14 15 17 6 8 9 10 11 12

0.50

12 13 14 16 17 19 8 9 10 11 12 13

0.72

16 17 18 19 21 22 10 11 12 13 14 15

Code 128 – Ean 128

Code Resolution (mm)

1.00

21 22 23 24 25 26 13 14 15 16 17 18

Table 3



Minimum Code Height for ACR Reading (mm)

45°

30°

Conveyor Speed (m/s)

0.5

1

1.5 2 2.5 3 0.5 1 1.5 2 2.5 3

0.25

8 9 10 12 13 15 5 6 8 9 10 11

0.30

9 9 11 12 14 15 6 7 8 9 10 12

0.33

9 10 11 13 14 16 6 7 8 9 11 12

0.38

10 11 12 14 15 17 7 8 9 10 11 12

0.50

13 13 14 16 17 19 8 9 10 11 12 13

0.72

17 18 18 19 21 22 11 11 12 13 14 15

Codabar

Code Resolution (mm)

1.00

23 23 24 25 26 26 14 15 15 16 17 18

Ratio 3:1; Interdigit = Module Size

Table 4



Minimum Code Height for ACR Reading (mm)

45°

30°

Conveyor Speed (m/s)

0.5

1

1.5 2 2.5 3 0.5 1 1.5 2 2.5 3

0.25

7 8 9 11 12 14 5 6 7 8 9 11

0.30

8 9 10 11 13 14 6 6 7 9 10 11

0.33

9 10 10 12 13 15 6 7 8 9 10 11

0.38

10 11 11 12 14 15 6 7 8 9 10 12

0.50

12 13 14 14 15 17 8 8 9 10 11 12

0.72

16 17 18 18 19 20 10 11 11 12 13 14

EAN 8-13, UPC-A

Code Resolution (mm)

1.00

21 22 23 24 24 25 13 14 15 15 16 16

Table 5