AMETEK CSW Series User Manual

Page 140

Advertising
background image

User Manual

California Instruments

140

CSW Series

VOLT MAX

Standard

Categories

A and Z

B 28V / 14V

RTCA

30.3

30.3

15.1

EUROCAE

30.3

29.3

14.6

Table 8-14: Normal Voltage Maximum

This test will change the output voltage from 28V or 14V to 30.3V or 15.1V. The test will last for
30 minutes. The

←

(backspace) will terminate the test at any time.

VOLT UNDER

This test applies to category Z and 28 volt category B equipment. The output voltage will drop to
10 volts and will ramp up at a rate of 0.15 volt/sec for the US standard and at a rate of 0.30
volt/sec for EUROCAE standard for 30 seconds before it returns to nominal value.

VOLT SURGE

This test will surge and sag the voltage to a level and duration specified Table 8-15 with 5
seconds between transients. The test is repeated three times.

Category

Surge

Sags

Volt

Dwell(msec)

Volt

Dwell(msec)

RTCA

EUR

US

EUR

A

40

40

30

15

17

30

B

40

40

30

15

17

30

Z

50

50

50

12

12

30

Table 8-15: Voltage Surge

POWER INTERRUPT

Refer to section POWER INTERRUPT.

Advertising