Additional electrical specifications, Input conditions – AMETEK HPD Series Operation Manual User Manual
Page 17

Section 1. Features and Specifications
Additional Electrical Specifications
Additional Electrical Specifications
Voltage Mode Transient Response
(Time for the output voltage to
recover to ±50 mV band for 50%
load change in the range of 25% to
100% of the rated load.)
Time delay from power on until
output stable
<500
s
1.5 s maximum
Input Conditions
Rated AC Input Voltage
120 Vac standard; 230/240 Vac AC200 option
Maximum AC Input Power
625 VA
Operational AC Input Voltage Range Single Unit: 104
–
127 Vac at 6 Arms
Dual Unit: 104
–
127 Vac at 12 Arms
AC 200 Option
Single Unit: 200
–
250 Vac at 3 Arms
Dual Unit: 200
–
250 Vac at 6 Arms
Maximum Input Current (per unit) at 6 A maximum at 104 Vac
nominal power line impedances
Input Frequency Range
47
–
63 Hz
5