Load considerations, Inductive loads, Outline drawings – AMETEK SFA Series User Manual
Page 32: Onsiderations, Inductive loads -8, Utline, Rawings, Table 2–6 maximum ac current ratings -8, Table 2–7 recommended lugs -8, Table 2–8. recommended sense connector tools -8

Installation
Sorensen SFA Series
Refer to Table 2–6 for AC input current requirements and Section 1.2.3 for
output current requirements.
Input Line Current
Input V
5 kW
10 kW
15 kW
20 kW
25 kW
30kW
Unit of
Measure
200-240VAC
21 41 62 83 103
124
340-440VAC
14
27 40 54 67 80
480VAC 13 26 39 52 65 78
Amps AC
per phase
Table 2–6 Maximum AC Current Ratings
Refer to Table 2–7 for input/output lug recommendations.
Lug Manufacturer
3U Models Input/Output
6U Models Input/Output
Panduit
“PN” Series or equivalent
“LCA” Series or equivalent
Table 2–7 Recommended Lugs
The recommended tools for installation and extraction of the sense connector
are listed next, in Table 2–8.
Tool
Manufacturer
Manufacturer P/N
Crimping Device
Molex
11-01-0197
Extracting Device
Molex
11-03-0044
Table 2–8. Recommended Sense Connector Tools
2.6
LOAD CONSIDERATIONS
2.6.1
I
NDUCTIVE
L
OADS
To prevent damage to the power supply from inductive loads, the SFA has
incorporated a overvoltage shutdown circuit on the output. The overvoltage is
preset for approximately 110% of the total rated output voltage. If the output
voltage exceeds this amount for more than a few milliseconds, the output will
shutdown. In order to reset the unit, the input standby switch, will need to be
cycled on and off.
2.7
OUTLINE DRAWINGS
Figure 2-1 and Figure 2–2, next, show the outlines and overall dimensions of
the 3U and 6U models of the SFA Series product line.
2-8
M550292-01 Rev G