Operation
SLM-Series AC/DC Electronic Load
3-16
M540072-01 Rev B
3.5.4 Over
Temperature Protection (OTP)
SLM-Series AC/DC Electronic load is provided with a temperature sensor. Over
temperature protection (OTP) is tripped when the heat dissipater temperature
exceeds about 85ºC ±5ºC, and the lower DM flashes “oTP”. Once the over
temperature condition is reset, the lower DM resumes normal display.
When OTP occurs, check the ambient working temperature and ventilation. The air
outlet on requires a distance of greater than 6 in / 15 cm from any obstruction, for
proper ventilation.
Model
OVP
OCP
OPP
SLH-500-4-1200
525.0 V
4.20 A
1260 VA
SLH-500-6-1800
525.0 V
6.30 A
1890 VA
SLH-300-12-1200
315.0 V
12.60 A
1260 VA
SLH-300-12-1800
315.0 V
12.60 A
1890 VA
SLH-300-18-1800
315.0 V
18.90 A
1890 VA
Table 3-5 SLH AC-series Protection Setting Values