Aplex Technology ARCHMI-912 User Manual

Page 29

Advertising
background image

ARCHMI-9XX Series User Manual

28

Procedures of CMOS clear:

a) Turn off the system and unplug the power cord from the power outlet.

b) To clear the CMOS settings, use the jumper cap to close pins 1 and 2 for

about 3 seconds then reinstall the jumper clip back to pins open.

c) Power on the system again.

d) When entering the POST screen, press the <ESC> or <DEL> key to enter

CMOS Setup Utility to load optimal defaults.

e) After the above operations, save changes and exit BIOS Setup.

9. BAT2:

(2.0mm Pitch 1x10 Wafer Pin Header), Smart battery Interface.

Pin#

Signal Name

Pin1

VCC_BAT1

Pin2

VCC_BAT1

Pin3

VCC_BAT1

Pin4

SMB_DAT_SW

Pin5

SMB_SCL_SW

Pin6

BAT1_TEMP

Pin7

Ground

Pin8

Ground

Pin9

Ground

Pin10

SET_BAT1_ON

Function

Specifications

Nominal voltage (3S1P)

11.1~12.6V

Charge voltage

12.6V

Charge current

0.5C

10. BAT_LED:

(2.0mm Pitch 1x4 Wafer Pin Header), The Charge status indicator for BAT2.

Pin1-Pin3: Charge LED status.

Pin2-Pin3: Discharge LED status.

Pin4-Pin3: EC LED status.

Pin#

Signal Name

Pin1

BAT2_LED+