3 sensor data records, Table 9-3, Sensor data records – Artesyn ATCA 7370 / ATCA 7370-S Installation and Use (January 2015) User Manual
Page 233: Fru information and sensor data records

FRU Information and Sensor Data Records
ATCA-7370/ATCA-7370-S Installation and Use (6806800P54H)
233
9.3
Sensor Data Records
The sensors available on the blades are detailed in the table below.
For sensor threshold definition please use the "ipmitool" found on
http://sourceforge.net/projects/ipmitool/files/ipmitool/
with
the parameter "sensor".
Table 9-3 Sensor Data Records
Sensor
Number Sensor Name Sensor Type
Event/Reading
Type
Event
Data
Byte 1 Event Data Byte 2
Event Data Byte 3
Event Threshold/
Description
Assertion
Deassertion Rearm
0
HS Carrier
Hot Swap
0xF0
Sensor-
specific
discrete
0x6F
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
[7:4] = Cause
[3:0] = Previous State
FRU ID
0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7
Asrt
Auto
1
Hot Swap
RTM
Hot Swap
0xF0
Sensor-
specific
discrete
0x6F
0x0
0x1
0x2
0x3
0x4
0x5
0x6
0x7
[7:4] = Cause
[3:0] = Previous State
FRU ID
0x0: M0
0x1: M1
0x2: M2
0x3: M3
0x4: M4
0x5: M5
0x6: M6
0x7: M7
Asrt
Auto
2
-48V A Volts Voltage
0x02
Threshold
0x01
reading
threshold
unr uc lnr lc
Asrt / Deass Auto