Hardware Preparation and Installation
2.1
Environmental and Power Requirements
2.1.1
Environmental Requirements
The following environmental requirements must not be exceeded.
The following table provides the environmental requirements for the module.
Thermal Requirements
A standard passive heat sink can be provided by Artesyn; 12 CFM system airflow volume (at
71
o
C) is needed for the heat sink to keep sufficient cooling to the module. Contact your
Artesyn sales representative for detailed thermal information.
Operating temperature refers to the temperature of the air circulating around the module
and not the component temperature.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
-40°C to +71°C
-50°C to +100°C
Humidity
to 100% RH
to 100
% RH
Vibration Sine (10mins/axis)
5 G, 15 to 2000Hz
Vibration Random (1hr/axis)
0.04 g
2
/Hz, 15 to 2000 Hz
(8GRMS)
Shock
30g/11 mS(half sine)
Altitude
-60 to 4000 m ASL