Clock structure, 1 overview, Table 5-1 – Artesyn COMX-P40x0 ENP2 Installation and Use (January 2015) User Manual
Page 89: Figure 5-1, Clock distribution, Chapter 5

Chapter 5
COMX-P40x0 ENP2 Installation and Use (6806800R95C)
89
Clock Structure
5.1
Overview
The COMX-P40x0 ENP2 module require several kinds of single ended and differential clocks for
booting up and normal operation. Following is the clock distribution tree:
The output frequency of the bank 1 and bank 2/3 SerDes clocks is selectable between 100 MHz
and 125 MHz. This must be set correctly by the carrier or corresponding CPU GPIO pins
depending on what RCW SerDes configuration is selected. For proper settings, refer
.
Figure 5-1
Clock Distribution
Table 5-1 Configuration of the frequency of SerDes reference clock by carrier
SerDes bank 1 reference clock select (pin B97 on
COM Express)
SerDes bank 2/3 reference clock select (pin B98
on COM Express)
Bank1_SEL_FS0=0, 100 MHz
Bank2_SEL_S1=0, 100 MHz
Bank 1
Bank 2
Bank 3
GE PHY
Crystal
ICS9FG104
(<50ps)
Crystal
ICS9FG104
(<50ps)
Crystal
100 MHz
OSC
RTC
32.768 KHz
24 MHz
OSC
USB
PHY
Device on
Carrier
COME Connector
100 MHz
100 MHz
125 MHz
USB
PHY
CY2305
Device on
Carrier
125 MHz
P40x0
100 MHz
32.768 KHz
60 MHz
24 MHz
Reference clock for
Bank 2#/3#
Reference clock
for Bank 1#