9 specifications, Table 1-5, Transition module cables – Artesyn MVME7616E Transition Module Installation and Use (April 2015) User Manual

Page 19: Table 1-6, Mvme761-0x1 specifications, General information

Advertising
background image

General Information

MVME7616E Transition Module Installation and Use (6806800A43D)

19

1.9

Specifications

The MVME761 transition module specifications are shown in the next table.

Table 1-5 Transition Module Cables

Part Number

Description

Included with the
MVME761-0x1

64-line flat ribbon cable with 96-pin DIN connectors that connects P2
on the MVME761transition module to J3 on the 3-row P2 Adapter or J4
on the 5-row P2 adapter; 13 inches long. (30-W2799B02A).

User-supplied

EIA-232-D DTE or DCE cable (pins used depend on the processor
VMEmodule)

User-supplied

Centronics- type parallel printer cable, male-to-male

User-supplied 20-conductor

cable; usually supplied with the modem

User-supplied 6-conductor

cable; usually supplied with the modem

CBL761HD26DB25

Straight-through adapter cable with male HD-26 connector and female
DB-25 connector, 3 feet long. (30-NW9302B27)

If you supply your own 64-line cable to connect the P2 adapter to the MVME761 transition module, the
cable should not be longer than 1.5 feet. A longer cable is likely to cause problems, especially for the
Ethernet and parallel port signals.

Table 1-6 MVME761-0x1 Specifications

Characteristics

Specifications

Power Requirements

+12 Vdc, 100 mA typical, 200 mA maximum
-12 Vdc, 100 mA (for some of the SIMs)

Operating temperature

0

o

to 55

o

C at chassis point of entry of forced air

(approximately 5 CFM)

Storage temperature

-40

o

to +85

o

C

Relative Humidity

5% to 90% (non-condensing)

Advertising