2 power requirements, Table 2-2, Operating voltages – Artesyn MVME8100 RTM (VXS1-RTM1) Installation and Use (April 2015) User Manual
Page 27: Hardware preparation and installation

Hardware Preparation and Installation
VXS1-RTM1 Installation and Use (6806800P46C)
27
2.2.2
Power Requirements
The RTM uses +5 V as a primary power source from the RP2 connector and converts to other
voltages internally using on board DC-DC converter. The following table shows the power
source required.
Relative humidity
To 95% RH
Vibration Sine
(10min/axis)
2G, 5 to 500Hz
Vibration Random
(1hr/axis)
0.002g
2
/Hz, 15
to 2000 Hz
Shock
20g/11mS
Table 2-1 VXS1-RTM1 Specifications (continued)
Characteristics
Value
Product Damage
High humidity and condensation on the board surface causes short circuits.
Do not operate the board outside the specified environmental limits.
Make sure the board is completely dry and there is no moisture on any surface before applying
power.
Table 2-2 Operating Voltages
Voltage
Minimum Nominal
Maximum
+5.0V
4.875V (-2.5%) 5.0V
5.25V (+5%)