30 installation – Avalon Firestyles 864 TRV GS2 Installation User Manual
Page 30

30 Installation
(for qualified installers only)
Travis Industries
4140611
100-01385
Rear Vent Configuration with Horizontal Termination (no vertical rise)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45° Elbow
Termination
See the charts below to
determine maximum vent
3 feet (0.915m)
0 feet
0 feet
4' max (1.22m)
• Exhaust Restrictor # 1 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
Vent with No 45° Elbow
3 feet (0.915m)
0 feet
0 feet
2' max (0.61m)
Vent with 1 45° Elbow
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal
Section(s)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1219mm) Horizontal
Section(s)
• Exhaust Restrictor # 1 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)