Proximity switch adjustment – Avery Dennison SS Finisher User Manual
Page 22

Users Manual SS Finisher
Operation •••• 22
Proximity Switch Adjustment
The Proximity Switch triggers the Ultrasonic Power Supply to begin generating
Ultrasonic energy during the cut. If the Proximity switch is not adjusted
properly, the Power Supply will not be triggered and the unit will not cut.
The Proximity Sensor Flag (see illustrations below) should be adjusted as
shown. The flag should be positioned so that there is a 0.015” (0.4mm) gap
between the Flag and the face of the Switch. And, in the home position, the
proximity flag should be approximately 25 degrees above the proximity sensor.
PROXIMITY SWITCH
FLAG
PROXIMITY
SWITCH
Note: Above view is looking down on top of machine.
PROXIMITY SENSOR
PROXIMITY FLAG
Note: Above view is looking at flag and sensor toward exit conveyor side of
machine.