Indicator lights, On line, Sensor – Avery Dennison SS Finisher User Manual
Page 26: Error

Users Manual SS Finisher
Trouble Shooting •••• 26
Indicator Lights
The AVERY DENNISON SS Finisher has three Indicator lights. These lights
are used along with the LCD display to tell the operator the current status of the
SS Finisher.
On Line
OFF
- Has not been powered on.
- Is in its power - up sequence.
- Failed the system test
ORANGE
- Passed system test
- Ready for operation.
GREEN
- Start button has been pressed - SS Finisher running
- Accumulator waiting for material.
Sensor
GREEN
- SS Finisher is stopped - light is on - sensor is positioned over a
sense mark
- Flashing light while SS Finisher is running - the sensor is in line
with the sense marks. See Color Mark Sensor Adjustment
Error
ORANGE
- System inter-lock triggered, see display for error.