Gas adjustment (Conversion to LPG)


All work must be carried out by a GASSAFE
registered engineer.

IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.



o

Remove the pan-stands, burners and
flame spreaders (A).






o

Unscrew the injector (B) and replace it with
the stipulated injector for the new gas
supply (see the table on the next page).






PRESSURE Ø

INJECTOR

THERMAL

CAPACITY

GAS TYPE

mbar

BURNER

1/100

mm

Nominal W

CONSUMPTION

Natural

gas – G20

20

Triple-

crown

71A-95B

4000

381

l/h

LPG –

G30/G31

28-30/37

Triple-

crown

80A-143B

4000

291

g/h

o

Reassemble all the burners carefully; in particular you should make
sure that the flame spreader is correctly placed on the burner.

o

IMPORTANT: The minimum flow adjustment process must be
completed before the appliance is next used.