Register description

KL6001

11


Terminal-specific register description

Process variables

R0: Number of data bytes in the send FIFO
The number of data items in the send FIFO is in the low byte. The high
byte is not used.

R1: Number of data bytes in the receive FIFO
The low byte contains the number of data in the receive FIFO. The high
byte is not used.

R2 - R5: no function

R6: Diagnostic register
High byte: not used
Low byte: status of the receive channel (bits 0 – 7)

Bit No.

Meaning

Bit 0

1

The receive buffer has overflown and arriving
data is lost.

Bit 1

1

Parity error has occurred.

Bit 2

1

Framing error has occurred.

Bit 3

1

Over run error has occurred.

Bit 4

1

Buffer is full

Bits 5 - 15

-

not used, don't change


Manufacturer parameters

R18: Buffer size
[0x0080]
Register R18 defines the number of data items in the receive FIFO as from
which the BUF_F bit is set in the status byte.

Low byte: BUF_F is set in the status if this value is reached.
High byte: not used

User parameters

R32: Baud rate:
[0x0006]

Bit No.

Baud rate

Bit 2 Bit 1 Bit 0

0 1 1

1200 Baud

1 0 0

2400 Baud

1 0 1

4800 Baud

1 1 0

9600 Baud [1 1 0]

1 1 1

19200 Baud

Bits 3 - 15

-

not used, don't change


The baud rate can also be set in accordance with the following equation:

Baud rate = 4 MHz/(16*(HB+1))

At the same time, 0xFF must be written into the low byte and the high byte
(HB) specifies the operator.