C621 C721 user manual.DOC

DISCHARGING PRODUCTS OF COMBUSTION


Extractor hoods connected directly to the outside must be
provided, to allow the products of combustion in the gas

appliance to be discharged (fig. 6.6).
If this is not possible, an electric fan may be used, attached to
the external wall or the window; the fan should have a capacity
to circulate air at an hourly rate of 3-5 times the total volume of

the kitchen (fig. 6.7).
The fan can only be installed if the room has suitable vents to
allow air to enter, as described under the heading "Choosing
suitable surroundings" (in compliance with the current laws in

force).

GAS HOBS

TECHNICAL INFORMATION FOR THE INSTALLER




Before installing the cook top, remove the protective film.
These cooking hobs are designed to be embedded into kitchen fixtures measuring 600 mm
in depth and from 20 to 40 mm thick, for 2 electrical plates hob.
In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown

in figs. 6.8a and 6.8b has to be made, keeping in consideration the following: -

• Within the fixture, between the bottom side of the cooker top and the upper surface of

any other appliance or internal shelf there must be a clearance of at least 30 mm;

• The cooker top must be kept no less than 50 mm away from any side wall;

• The cooker top must be kept at a distance of no less than 50 mm from the rear wall.

• There must be a distance of at least 650 mm between the hob and any wall cupboard or

extractor hood positioned immediately above (see figs. 6.9a and 6.9b).

• The coatings of the walls of the unit or appliances near the cook top must be heat

resistant ("Y" protection against heating in compliance with standards EN 60335-2-6).


Do not install the appliance near inflammable materials (e.g.. curtains).