INSTALLATION CLEARANCES

Minimum clearances to combustible construction are:
• Top, Back and Sides of Recessed
Cabinet .. . . . . . . . . . . . . . . . . . . . .0" Min.
• Drywall to Sides of Front Face .. . .0" Min.
• Framing at Nailing Flanges.. . . . . .0" Min.
• Ceiling to Opening.. . . . . . . . . . . .36" Min.

Facing Material May
Be Noncombustible
Wall Treatments or
Combustible Wood

Combustible Wood
Mantels and Trims
May Extend Above
Profile Shown when
Maintained within
30° Parameter
Shown

Framed
Material

Top of Cabinet

Note: All Mantel Clearances
are Measured from Top of
Fireplace Opening

30°

16

5

/

8

"

Ref.

9

5

/

8

" Ref.

12" Ref.

13

3

/

4

"

4

1

/

2

"

1

1

/

2

"

1

3

/

4

"

10

1

/

2

" Min.

10

1

/

2

"

Figure 3 - Mantel Clearances

Top View of Fireplace

Safe Zone

5"

3"

30°

1

3

/

4

" Max.

Minimum 10" from

Perpendicular Side Wall

Edge of Firebox
Opening

Combustible
MaterialMust
Not Overlap
Front Face

Figure 4 - Mantel Side Clearances

INSTALLATION

Continued

• Floor .. . . . . . . . . . . . . . . . . . . . . . .0" Min.
• Front .. . . . . . . . . . . . . . . . . . . . . .36" Min.
• Perpendicular Side Wall .. . . . . . .10" Min.

Mantel Clearances
For mantel clearances see Figures 3 and 4.