Installation, Platform/subflooring, Continued built-in installation – Desa E36L User Manual

Page 5: Electrical installation

Advertising
background image

www.desatech.com

111076-01F

5

INSTALLATION

Continued

BUILT-IN INSTALLATION

Built-in installations require a framed enclo-
sure constructed of 2" x 4" or heavier lumber
and sized in accordance with Figure 5. This
allows unit to slide into opening and be nailed
to stud at sides and top nailing flanges. These
flanges accept 5/8" drywall or plywood board
to finish unit flush to face. Optional trim ac-
cessories are available that will extend 1/2"
over rough edge of wall opening (see Acces-
sories
, page 25).
IMPORTANT: If installing a perimeter trim kit,
you must install shoulder screws before insert-
ing fireplace into opening. See instructions
included with trim kit. If installing a mantel,
you must follow clearance instructions (see
Installation Clearances, page 4).
A hearth extension is suggested for a more
pleasing appearance. The fireplace may be
raised on a wood or non-combustible platform
supporting its entire width and depth and
extending in front of the fireplace as long as
louvers are not obstructed.
Note: When installing fireplace in cold cli-
mates against a non-insulated exterior wall,
wall must be fully insulated in accordance with
local building code.

VE32 = 34

5

/

8

"

VE36 = 41

1

/

4

"

VE32 = 15

7

/

8

"

VE36 = 17

1

/

4

"

VE32 = 32

5

/

8

"

VE36 = 36

1

/

4

"

Platform/Subflooring

Figure 5 - Framing Dimensions

VE32 = 37

5

/

8

"

VE36 = 42

3

/

8

"

VE32 = 26

5

/

8

"

VE36 = 29

3

/

8

"

VE32 = 52

3

/

4

"

VE36 = 58

1

/

4

"

11

5

/

8

"

These Dimensions
Allow for 11

5

/

8

" of

Clearance to Side
Wall of Fireplace
and 10' Clearance
to Perpendicular
Side Walls

Figure 6 - Corner Dimensions

ELECTRICAL INSTALLATION

WARNING: Any electrical re-

wiring of this appliance must be

done by a qualified electrician.

This wiring must be done in ac-

cordance with local codes and/or

in the U.S.A. with the current, Na-

tional Electrical Code ANSI/NFPA

No 70 and in Canada with CSA

C22.1 Canadian Electric code.

This fireplace should be con-

nected to a dedicated 15 Amp,

circuit as other appliances may

cause the circuit breaker to trip

or fuse to blow when fireplace

is in operation.

A junction box with universal strain adaptor is
provided to hard wire unit to a 15 amp, 120
Volt 60 Hz grounded circuit. If necessary,
junction box may be relocated to route sup-
ply to left side.
1. Remove 2 screws and outer cover on right

side (see Figure 7, page 6).

2. Remove inner screw securing junction

box.

3. Slide junction box up until mounting tab

is lined up to notch in outer cabinet.

4. Swing box out and slip retaining flange

out through slot in outer cabinet.

5. Remove 2 screws and outer cover on left

side and reattach on right side of outer
cabinet.