Solar sizing worksheet – Codan Radio Radio Repeater Systems Training Guide User Manual

Page 35

Advertising
background image

RADIO REPEATER SYSTEM | TRAINING GUIDE

Chapter 3: Repeater System Equipment Page 27

SOLAR SIZING WORKSHEET

SITE NAME BRIDGE ARS

DATA POINT

LYTTON

AVERAGE YEARLY BRIGHT SUNSHINE HOURS (BSH)

1927

ADJUSTED (+ or - a +5 percent) TOTAL BSH

2023

AVERAGE PEAK HOURS PER DAY (total BSH x 0.0017) = B =

3.44

AVERAGE ANNUAL TEMPERATURE (at monitor point) c =

+9

ADJUSTED FOR SITE (c - adiabatic lapse rate) +20 = C =

23.5

DUTY CYCLE (shown as a decimal, eg. 8% = .08) = dc =

0.08

TOTAL DAILY NORMAL OPERATING HOURS a =

9

h

TOTAL STANDBY CURRENT (24 x Rx(I)) = b =

2.0

Ah

TOTAL TX CURRENT (a x Tx(I) x dc) = c =

1.6

Ah

TOTAL DAILY REQUIREMENT (b + c) = r =

3.6

Ah

REPEATER OPERATING VOLTAGE V =

12.5 Volts

BATTERY TYPE Ni-Cad VOLTS PER CELL v =

1.2

Volts

NUMBER OF CELLS REQUIRED IN SERIES (V/v) = VI =

10

cells

ONE BANK OF CELLS WILL GIVE (100 / r)

28 DAYS OF STORAGE

CHARGE VOLTAGE PER CELL CV =

1.4

Volts

REVERSE CURRENT DIODE OR REGULATOR LOSS D =

0

Volts

NOMINAL PANEL VOLTAGE (from manufacturers data) = m =

14

Volts

PANEL O/P VOLT REQ’D (D+R+(VIxCV)+(0.004(C x m))) = L =

15.8 Volts

PANEL CURRENT (from man. power graph) at L volts = M =

1.9

A

MODULE CURRENT PER DAY (B x M) = M1 =

6.5

A

NUMBER OF PANELS REQUIRED = (r / M1) =

0.5

modules