1 dc operation – applying power – Comtech EF Data CDM-800 User Manual
Page 49

CDM-800 Gateway Router
Revision 1
Rear Panel Connections
MN-CDM800
3–13
3.3.3
48V Direct Current (DC) Power Interface (Optional)
Figure 3-8. CDM-800 DC Power Interface
3.3.3.1 DC Operation – Applying Power
Figure 3-9. Applying DC Power to the CDM-800
To apply DC power to the CDM‐800:
• First, connect the user‐supplied (+) and (–) DC power leads to their respective
terminals. Number 18 AWG minimum wires are recommended.
• Then, connect the user‐supplied DC power leads to the power source.
• Finally, switch the unit ON.
Feature
Description
1
On / Off Switch
2
Screw‐in Fuse Holders / Receptacles
3
Power Terminal Block
DC Power Specifications
Input Power
25W (typical)
245W (maximum with BUC)
Input Voltage
48V DC, nominal
(36V to 60V)
Connector Type
Terminal Block
Fuse Protection
(2X) 20mm Slow‐blow type fuses:
T3A (3.0A) Main
T5A (5.0A) (BUC)