Up converter, Specifications, A.1.4 up converter – Comtech EF Data HPCST-5000 User Manual
Page 178: A.1.4.1 specifications

Configurations
High-Power C-Band Satellite Terminal
A–8
Rev. 0
A.1.4 Up
Converter
The function of the up converter is to convert the 140 MHz IF signal used in the indoor
unit modem to a C-Band signal sent to the HPA.
Refer to Figure A-5 for a functional block diagram of the up converter.
A.1.4.1 Specifications
Refer to Table A-4 for specifications.
Table A-4. Up Converter Specifications
Down Converter
Input Frequency
140.0 MHz,
! 36 MHz
Input Connector
SMA Female
Input Impedance
50
#
Input VSWR
1:3:1
Output Frequency
5845.0 to 6425.0 MHz
Output Connector
SMA Female
Output VSWR
1:5:1
1.0 dB Compression
+10.0 dBm
RF Local Oscillator Input
Frequency
1112.5 MHz
Level
+8.0 dBm
Connector
SMA Female
Return Loss
14.0 dB
Impedance
50
#
RF Synthesizer Input
Frequency
4592.5 to 5172.5 MHz
Level
+8.0 dBm
Connector
SMA Female
Return Loss
14.0 dB
Impedance
50
#