2 c-band sspa external connections – Comtech EF Data HPCST-5000 User Manual
Page 51

High Power C-Band Satellite Terminal
External Connections
Rev. 0
2–7
2.1.2
C-Band SSPA External Connections
WARNING
Always terminate the output waveguide of the amplifier with an RF load
capable of dissipating full CW RF power. Do not look into the output port of
the powered RF amplifier. Severe bodily harm can be the result.
Connections between the C-Band SSPA and other equipment are made through five
connectors. These connectors are listed in Table 2-3, and their locations are shown in
Figure 2-3. The use of each connector is described in the following paragraphs.
Figure 2-3. C-Band SSPA External Connections
Table 2-3. C-Band SSPA External Connections
Name
Ref Des
Connector Type
Function
RF Input
J1
N-Type, female
RF Input
Discrete Interface
J3
MS3112E16-26P (M)
M&C port for RFT500
RF Output Monitor Port
J4
N-Type, female
Independent M&C of output
power levels (-40 dB coupled)
AC Line
J5
MS3102R16-10P (M)
Prime Power Supply
RF Output
J7
CPR-137G (Grooved)
W/G connection