Comtech EF Data KST-12025 User Manual
Page 68

Redundant System Installation
KST-12025 Ku-Band Satellite Terminal
3–14
Rev. 1
6. Mount the RFTs as follows:
a.
Lift the RFT into position on
the vertical pole.
b. Slip a 14” unistrut over each
of pair of threaded rods
(upper and lower).
Note: Install the 14” unistruts
with the open face toward the
pole, as illustrated.
c.
Install a 5/16” flat washer,
5/16” split lockwasher, and
5/16-18 nut on each threaded
rod.
d. Position the RFT, as desired,
and tighten the 5/16-18 nuts
installed in Step 6.c.
e.
Slide the pipe blocks in until
they contact the vertical pole.
Then, firmly tighten the
5/16-18 bolts.
3.3.2.2 Square
Pole
For square vertical pole installation, follow the steps in Section 3.3.2.1, with the
following exceptions:
•
Do not perform Step 4.
•
Do not perform Step 6.e.