Page 90: 3 terminal default conditions, 4 theory of operation

Advertising
background image

Theory of Operation

KST-12025 Ku-Band Satellite Terminal

5–4

Rev. 1

5.1.2.1

Remote Interface Specification

Refer to Appendix A.

5.1.3

Terminal Default Conditions

On initial power-up, the unit will default to the following parameters.

Parameter

Default

Baud Rate

[9600]

Parity

[Even]

Device Address

[1]

U/C Gain

[10.0]

D/C Gain

[0.0]

RF Output

[OFF]

U/C Frequency

[Low end of range]

D/C Frequency

[Low end of range]

5.1.4

Theory of Operation

Refer to Figure 5-3 for a functional block diagram of the M&C.

The M&C PCB performs the following operations:

•

Receives the desired frequency from either the remote EIA-232-C/485 or local
keypad, and after converting it to a synthesizer setting, stores it to the applicable
synthesizer output latch.

•

Reads the thermistors located in the up converter, down converter, and high-
power amplifier, and converts them to temperatures for display.

•

Reads the characterization EEPROMs in the up converter, down converter, and
high-power amplifier, and calculates an Automatic Gain Control (AGC) voltage
based on frequency and temperature to linearize the respective module.

•

Turns the fan on or off, depending on the temperature.

•

Receives fault inputs from all modules, and presents them to the remote EIA-
232-C/485 and the optional local keypad display.

•

Performs an initial current sense on the LNA, and stores the reading in
EEPROM. Subsequent current sense readings are taken and compared to the
initial reading to determine a fault.