7.2.2.1 Start of Packet

Controller-to-Target: This is the character ‘<’ (ASCII code 60).

Target-to-Controller: This is the character ‘>’ (ASCII code 62).

The ‘<’ and ‘>’ characters indicate the start of packet. They may not appear anywhere else within the body of the message.

7.2.2.2 Target Address

Up to 9,999 devices can be uniquely addressed; in EIA-485 applications, the permissible range of values is 1 to 9999. The address is

programmed into a Target unit using the remote control port.

Each block converter module has its own address:

Module

Address

MBT-5000

Base

Block Converter A

Base + 1

Block Converter B

Base + 2

If several devices share an EIA-485 bus, it must be noted that the MBT-5000 will require three addresses, and should be spaced apart

accordingly.

The Controller sends a packet with the address of a Target – the destination of the packet. When the Target responds, the

address used is the same address, to indicate to the Controller the source of the packet. The Controller does not have its

own address.

7.2.2.3 Address Delimiter

This is the “forward slash” character '/ ' (ASCII code 47).