1 optional -48v dc operation – apply power – Comtech EF Data MBT-5000 User Manual
Page 45

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Rear Panel Connections
Revision 4
3–13
3.3.3
Optional -48V Direct Current (DC) Power Interface
Figure 3-9. MBT-5000 Optional DC Power Interface
3.3.3.1 Optional -48V DC Operation – Apply Power
Figure 3-10. Apply DC Power to the MBT-5000
To apply DC power to the MBT-5000, do these steps:
• First, connect the user-supplied (+) and (–) DC power leads to their respective terminals.
Number 18 AWG minimum wires are recommended.
• Then, connect the user-supplied DC power leads to the power source.
• Finally, switch the unit ON.
Feature
Description
1
Power Terminal Block
2
On / Off Switch
3
Fuse Holder
DC Power Specifications
Input Power
75W maximum, less than 65W typical
Input Voltage
36 to 72 VDC
Connector Type
Terminal Block
Fuse Protection
(1X) 3.15A 5 x 20mm slow-blow fuse