to accept the receiver. To facilitate custom installations, a Adaptor Plug is provided.

The Adaptor Plug has a 12 position socket. Wire the Adaptor Plug to your locomotive

with the connections as shown below.
1) POWERING THE Revolution TE. The Revolution TE is designed to work

from either track power or on board battery power of at least 12 volts DC to a

maximum of 24 volts DC. The receiver is self-protected for polarity and input

current. However, if you use a battery, you should install a 3-amp fuse directly

from the battery before any other wiring is connected. The fuse will protect your

wiring and the battery from damage in case of an accidental short circuit.

2) ISOLATE THE MOTOR(S). The motor(s) MUST be isolated from ALL other

wiring before the Revolution TE can be installed in a locomotive. This is critically

important. Failure to isolate the motors will cause the receiver to malfunction or

possibly fail. After you have located and disconnected the motor wires from the

locomotive, use an ohmmeter to check the resistance between the motor wires and

any other wires that you can find in the locomotive. If any connection is indicated

at all, locate the connection and isolate the motor wires.

3) ADAPTOR PLUG CONNECTIONS. All wiring connections should be soldered

and insulated with heat shrink tubing or electrical tape.

I.D.

USE

TRADITIONAL WIRE COLOR

TR+

RIGHT SIDE TRACK PICK-UP

Black (BLK)

MOT+

MOTOR POSITIVE POWER

Gray (GRY)

HD1

REAR HEADLIGHT NEGATIVE

Yellow (YEL)

HD COM

FRONT HEADLIGHT POSITIVE

Blue (BLU)

HD2

FRONT HEADLIGHT NEGATIVE

White (WHT)

MOT-

MOTOR NEGATIVE POWER

Orange (ORG)

TRK-

LEFT SIDE TRACK PICK-UP

Red (RED)

Connect the motor wires: Solder the motor’s Right Side terminal to the Adaptor

Plug at MOT+. Solder the motor’s Left Side terminal to MOT-.

Connect the power wires: For track power installations, solder the Right Side

power pick-ups to TR+. Solder the Left Side power pick-ups to TRK-. For

Battery Power installations, Battery installations should include a 3-amp fuse in

TR+ RIGHT SIDE TRACK PICK-UP

TRK- LEFT SIDE TRACK PICK-UP

HD1 REAR HEADLIGHT NEGATIVE

HD2 FRONT HEADLIGHT NEGATIVE

HD COM FRONT HEADLIGHT POSITIVE

MOT+ MOTOR POSITIVE POWER

MOT- MOTOR NEGATIVE POWER