SNMP Factory Defaults

Read Community:

public

Read/Write Community:

private

Notification Timeout:

1 second

Notification Retry Count:

3

Lead Configuration Change:

0 seconds


Download the MIB from the iPIO support pages at

http:Dataprobe.com\support.aspx


The iPIO is configurable for what events trigger SNMP Traps. See section

7.5 SNMP Setup

Input. Email on any input change

Relay. Email on any relay change

Communication. Email on any change in communication status to the remotes.

Configuration. Email on any configuration change.

5.4.

Email Notifications

The iPIO will send email for a number of events. Up to two email addresses can be specified to receive
emails. The types of events that generate emails are also configurable. See section

7.3 Email Setup

. The

events that can generate emails are:

Input. Email on any input change

Relay. Email on any relay change

Communication. Email on any change in communication status to the remotes.

Configuration. Email on any configuration change.


Email Syntax for input change

From: <your from account>
Date: Thu, Oct 3, 2013 at 5:14 PM
Subject: Input Change
To: <your to address>


<Location Name of iPIO>
Input <input number> <input name> is <state name>


Example:

From: <[email protected]>
Date: Thu, Oct 3, 2013 at 5:14 PM
Subject: Input Change
To: [email protected]


Shop Floor - Houston
Input 16 Back Door is Open


Other emails use similar syntax.