Removing and replacing the belt – DR Power 5.00 HP Power Wagon User Manual

Page 23

Advertising
background image

DR POWERWAGON 5.0 Safety & Operating Instructions

20

Figure 15

Figure 16

Removing and Replacing the Belt








Tools Needed:

7/16" socket and extension

9/16" socket

1. Position the machine on a

level surface and set the
parking brake.

2. Tip the bed forward. (Figures 9

& 10)

3. Remove the belt guard by

removing the two bolts at the
front and the single bolt at the
rear using a 7/16" socket.
(Figure 15)

4. Loosen the belt guide bolts

using a 9/16" socket.

5. Pull on the idler arm and

spring to lessen the tension on
the belt and slide the belt from
the idler arm and clutch pulley.
(Figure 16)

6. Remove the belt from the

transmission pulley at the
front of the machine. (Figure
17
).

7. Remove the belt from the

drive pulley under the engine.
(Figure 14)

8. Install the new belt on the

drive pulley first, then the
transmission pulley and then
the idler and clutch pulleys.
Make sure the new belt is INSIDE the belt guide. (Figure 14)

WARNING!

Before performing any maintenance procedure, stop the

engine, set the parking brake and disconnect the spark plug wire.

Important!

Use only DR belts on your machine. They have been thoroughly

tested and proven for many hours of use.

Idler Arm

Spring

Clutch Pulley

Front Bolts

Rear Bolt

Belt Guard

Belt Guide
Bolts