Fieldpiece LT17AW - Wireless Digital Multimeter User Manual

Fieldpiece, Quick start, Certifications

Advertising
background image

01

06

02

07

03

08

04

09

05

10

Quick Start

Receive a Wireless Reading

1. Select RECV on main dial.

2. Hold SYNC for one second.

3. Set partner device to transmitting switch

position.

4. Hold SYNC on partner device for one second.

When connection is made

and

icons

will display on the top of LT17AW screen.

5. Enjoy the wireless goodness!

Certifications

IEC/EN61010-1

EMC EN61326-1

FCC

C-Tick (N22675)

WEEE

RoHS compliant

CATIII: Is for measurements performed in the

building installation.

Description

As a proud owner of the first wireless digital

multimeter, LT17AW, you are well on your way to

eliminating tangled wires. LT17AW will give you

the power to receive measurements wirelessly

from anywhere on the jobsite. For instance, you

can transmit indoor wet bulb measurements

over-the-air while you work at the condenser.

Your LT17AW can receive measurements

wirelessly from any Fieldpiece accessory head

connected to a Fieldpiece wireless transmitter

like ET2W or EH4W.

In addition, your LT17AW can also transmit

wirelessly any measurement range on the dial

to any Fieldpiece wireless receiver, like EH4W,

HG3, or another LT17AW.

Your LT17AW easily syncs with compatible

wireless Fieldpiece transmitters and receivers.

LT17AW has a wide wireless range to cover the

whole jobsite.

Your LT17AW remembers the last meter it was

synced with, so there is no need to constantly

resync the same pairs. Note: this feature is

available when synched to single-link receivers

such as the LT17AW, ET2W, and EH4W.

Controls

Rotate dial to the function you want to use.

Hold to connect to other Fieldpiece

wireless products.

Press to activate MAX or MIN. Hold to

return to normal mode.

Press to freeze reading on display.

Press to toggle backlight on and off.

Fieldpiece

Wireless

Digital Multimeter

OPERATOR'S

MANUAL

Model LT17AW

Display

Battery Life (replace 9V if blinking)

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Auto Power Off Enabled

Wireless Icon

Singal Strength Bars

k M

MAXMIN HOLD

LT17AW

EH4W

HOLD (freezes current reading)

k M

MAXMIN HOLD

LT17AW

EH4W

MAX (displays maximum reading)

k M

MAXMIN HOLD

LT17AW

EH4W

MIN (displays minimum reading)

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Continuity Test

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Kilo Unit (10

3

, one thousand)

O

F

F

MFD

NCV

V

AC

V

DC

A

AC

Hz

Hz

%

°C

°F

SC56

AUTO OFF

TRUE RMS

CAT III

600V

TEMP

K-TYPE

30V

MAX

SEL

HOLD

INRUSH

Mega Unit (10

6

, one million)

Specifications

Wireless range: Up to 75 feet (23m) line of sight

Minimum Wireless Distance: Up to 1 foot (30cm)

Wireless Frequency: 910MHz to 920MHz (US), 868.1MHz to

868.5MHz (European)

Display: 5000 count liquid crystal display with backlight

Overrange: (OL) or (-OL) is displayed Zero: Automatic

Measurement rate: 2.5 times per second, nominal

Operating environment: 32°F to 122°F (0°C to 50°C) at <70% RH

Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH

(with battery removed)

Accuracy: Stated accuracy @ 73°F±9°F (23°C±5°C), <75%RH

Temperature coefficient: 0.1 x (specified accuracy) per °C [0°C to

19°C (32°F to 66°F), 28°C to 50° C(82°F to 122°F)]

APO (Auto Power Off): Approx. 30 minutes. Disable APO by

holding the MAX/MIN button while turning on the meter. APO

will not show on the LCD. APO is disabled in any wireless mode.

Backlight: Bright blue backlight. Approx 3 minutes.

Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22

Battery life: 100 hours typical alkaline

Low battery indication: Battery icon will be empty (

). "bAtt"

displays along with a continuous beep when the battery voltage

drops below the operating level. Meter shuts off in 5 seconds.

Dimensions: 165mm(H) x 78mm(W) x 50mm(D)

Weight: Approx. 315g including rubber boot

Overload protection: 600 VDC or 600VAC rms unless otherwise

stated. 15 seconds on 500mV range.

Test leads: Use the test leads that are supplied with the meter or UL

listed test leads rated CATIII 600V or above.

Safety: Designed to meet IEC 61010-1(EN 61010-1), CAT III 600V,

Class II, polution degree 2, indoor use and comply with CE.

UL61010-1.

Functions

Wireless Receiver Mode

Use your LT17AW to wirelessly receive

measurements from any Fieldpiece wireless

transmitter you have set up on the jobsite.

LT17AW

1. Select RECV switch position. Hold SYNC but-

ton for one second. Search pattern initiates.

Fieldpiece Transmitters

2. Connect any Fieldpiece accessory head to a

Fieldpiece transmitter.

3. Select DC switch position for all accessory

heads except ACH4 (AC switch position).

4. Hold SYNC button for one second.

Note: When a connection is made, the signal

strength and battery life of the partner de-

vice will be displayed on top of the LT17AW

screen. If no partner device is found within

two minutes, the LT17AW will stop searching.

Wireless Transmitter Mode

Transmit measurements wirelessly direct

from LT17AW or from an attached Fieldpiece

accessory head to Fieldpiece wireless receivers,

which lets you be in multiple places at once.

LT17AW Sending Direct Measurements

1. Select any switch position other than RECV.

2. Hold SYNC for one second until meter beeps.

Search pattern will initiate on LCD.

Fieldpiece Receivers

3. Select RECV switch position. Hold SYNC but-

ton for one second. For HG3, highlight the test

line and hold SYNC button for one second.

Note: When a connection is made, the signal

strength to the partner device will display on

LT17AW. If no partner device is found within

two minutes, the LT17AW will stop searching.

LT17AW Transmitting Accessory Head Reading

1. Connect any Fieldpiece accessory head to the

LT17AW by removing the probe tips from test

leads and plugging into accessory head plugs.

Insert test leads to COM and VΩ ports.

2. Select a mVDC range for all accessories except

for ACH4 (mVAC range).

3. Hold the SYNC button for one second.

4. Follow "Fieldpiece Receivers" section above.

Wireless Auto-Connection

When powered on, LT17AW will search

and connect to the last connected single-link

partner device (LT17AW, ET2W, or EH4W).

Temperature (°F/°C)

Plug any K-type thermocouple directly into the meter to measure

temperature. Cold junction is located “inside meter” and allows for

extremely accurate measurements even in rapidly changing ambient

temperatures (going from rooftop to freezer). No adapter is required.

See Temp Calibration section for calibration instructions.

Range: -30°F to 1400°F, (-35°C to 750°C) Resolution: 0.1°

Accuracy: ±(1°F) 32°F to 120°F, ±(1°C) 0°C to 49°C

±(1%+1.5°F) 32°F to 750°F, ±(1%+1°C) 0°C to 399°C

±(3%+4°F) -30°F to 32°F, ±(3%+3°C) -35°C to 0°C

±(3%+4°F) 750°F to 1400°F, ±(3%+3°C) 400°C to 750°C

Sensor type: K-type thermocouple

Overload protection: 30 VDC or 30VAC rms

Voltage AC (VAC) (50Hz-500Hz)

Test power lines (120, 220, 480), test 24V going to controls, and

test for transformer failure.

Ranges: 500mV, 5000mV, 50V, 500V, 600V Resolution: 0.1mV

Accuracy: ±(1.2% + 6) 500mV to 50V ranges

±(2%+6) 500V and 600V ranges

Input Impedance: 10MΩ

Voltage DC (VDC)

Select VDC and the range will automatically be selected to give

the best resolution.

Ranges: 500mV, 5000mV, 50V, 500V, 600V Resolution: 0.1mV

Accuracy: ±(0.5% + 3)

Input impedance: 10MΩ

FUSED

200

m

A

MAX

FUSED

30V

MAX

WIRELESS

ENABLED

MAX/MIN

SYNC

HOLD

CAT.III

MAX

600V

15 SEC FOR

500

m

V

RANGE

AUTO-OFF

500

600

600

50

5000m

500m

500µ

50m

200m

200m

500m

5000m

50m

50500

500µ

500

750

500

1400

200

2

K

200

20

M

2

K

200

K

20

RECV

k M

MAXMIN HOLD

LT17AW

EH4W

500

600

600

50

5000m

500m

500µ

50m

200m

200m

500m

5000m

50m

50500

500µ

500

750

500

1400

200

2

K

200

20

M

2

K

200

K

20

RECV

FUSED

200

m

A

MAX

FUSED

30V

MAX

CAT.III

MAX

600V

15 SEC FOR

500

m

V

RANGE

Unplug Leads and Slide

TEMP Switch to the Left

500

600

600

50

5000m

500m

500µ

50m

200m

200m

500m

5000m

50m

50500

500µ

500

750

500

1400

200

2

K

200

20

M

2

K

200

K

20

RECV

500

600

600

50

5000m

500m

500µ

50m

200m

200m

500m

5000m

50m

50500

500µ

500

750

500

1400

200

2

K

200

20

M

2

K

200

K

20

RECV

500

600

600

50

5000m

500m

500µ

50m

200m

200m

500m

5000m

50m

50500

500µ

500

750

500

1400

200

2

K

200

20

M

2

K

200

K

20

RECV

MAX/MIN

SYNC

HOLD

MAX/MIN

SYNC

HOLD

MAX/MIN

SYNC

HOLD

MAX/MIN

SYNC

HOLD

Advertising