Fieldpiece SMAN320 - 3-Port Digital Manifold User Manual

Fieldpiece, Quick start, Certifications

Advertising
background image

01

06

02

07

03

08

04

09

05

10

Quick Start

1 Install six AA batteries into rear battery com-

partment. Batteries included in packaging.

2 Press the center blue button for 1 second to

turn on your new manifold.

3 Connect hoses and ATB1 thermocouples to

the manifold and the system.

4 See all your pressure and temperature mea-

surements in real-time all at once!

Certifications

C-Tick (N22675)

CE

RoHS Compliant

Description

Your SMAN320 is a handy two-valve Digital

Manifold for HVACR professionals. See all your

pressures and temperatures at the same time

on the redesigned large display with bright

blue backlight.

SMAN320 combines high precision, absolute

pressure sensors, a superheat/subcooling

calculator, and dual temperature measurements.

Your SMAN320 calculates and displays target

superheat and actual superheat to verify proper

charge.

SMAN320 is designed to meet the demands

of HVACR field service with a rugged rubber

boot for durability, a strong metal hanger for

easy storage. SMAN320 has a very intuitive user

interface and long battery life.

Your SMAN comes pre-programmed with

the most accurate P-T charts for 45 of the most

common refrigerants in the field so you are

always prepared for any job.

Fieldpiece

Digital Manifold

OPERATOR'S MANUAL

Model SMAN320

Controls

1 Insert Type K thermocouple plugs here.

2 Temperature calibration pots.

3 Press to zero atmospheric pressure.

4 Press to calibrate to refrigerant tank.

(See Advanced Pressure Calibration section.)

5 Press to confirm selection.

6 Press/hold to cycle through refrigerants.

7 Press to enter Target Superheat mode.

8 Press to scroll up/down to adjust values.

9 Press to adjust units.

10 Hold 1 second to power on or off. Press to toggle backlight.

11 Turn clockwise to close High side port.

12 Turn clockwise to close Low side port.

Functions

Superheat and Subcooling

Your SMAN320 calculates and displays both superheat and

subcooling simultaneously.

1 Select the appropriate refrigerant using the REFRIGERANT button.

2 Connect EPA approved refrigerant hoses to low and high side on

SMAN320. Plug Type K ATB1 thermocouples into SLT and LLT.

3 Connect your SMAN320 to the system:

Superheat: Hand tighten low side hose to suction line service

port. Place the SLT ATB1 thermocouple on the suction line with

Velcro strap between the evaporator and compressor, no closer

than 6 inches to compressor.

Subcooling: Hand tighten high side hose to liquid line service

port. Attach the LLT ATB1 thermocouple on the liquid line with

Velcro strap between the condenser and expansion valve (TXV), as

close to the service port as possible.

4 After turning the system on or making any adjustments to

the system wait 15 minutes before charging by superheat or

subcooling to ensure the system is stabilized.

5 To add or remove refrigerant connect a refrigerant or recovery

tank to the center port on SMAN320. Follow charging or recovery

practices from manufacturer. Use the low side and high side

valves on SMAN320 to charge or recover refrigerant as needed. Let

system stabilize again for 15 minutes.

Note: When superheat and/or subcooling cannot be calculated an

"OL" or "-OL" will be displayed. Please check the following:

1 The correct refrigerant is selected on the SMAN.

2 The pipe thermocouples are plugged into SLT/LLT ports and are in

good working condition.

3 The pipe thermocouples are attached in the appropriate location on

the system. See step 3 above for details.

Target Superheat

Target Superheat is useful for charging fixed orifice air conditioning

systems. Your SMAN will calculate the target superheat for you. Just

manually input the IDWB (indoor wet bulb) and ODDB (outdoor dry

bulb) temperatures into the SMAN.

Input IDWB and ODDB manually

1 Press Target SH button to enter Target SH mode. IDWB will begin

blinking indicating it is ready for an input.

2 Press UP or DOWN ARROW to toggle between IDWB or ODDB

input. Hold ENTER to select which temperature you want to input

first, either IDWB or ODDB. The far left digit of IDWB or ODDB will

begin blinking indicating manual input mode is ready.

3 Press the UP or DOWN ARROW to change values and press ENTER

to lock in each digit. Once the last digit for ODDB or IDWB is locked

in, the calculated target superheat will show in the center column

of the display. A solid HOLD will display to the left of the TSH

calculation indicating a static target superheat calculation.

Note: If the inputted temperature is out of the calculable range for

IDWB or ODDB an "Err" will flash once and a double beep will

sound. IDWB range (40°F to 125°F, 4.4°C to 51.7°C) and ODDB

range (50°F to 140°F, 10°C to 60°C). Re-input a temperature

within these ranges to calculate target superheat.

Changing Units

Your SMAN can display pressure and temperature measurements in

English, Metric or combination of both units.

1 Press UNITS to enter unit selection screen.

2 Use ARROW to select your desired pressure units. Press ENTER.

3 Use ARROW to select your desired temperature units. Press ENTER

to return to pressure units.

4 Press UNITS to return to normal SMAN display.

Specifications

Display size: 5 inches (diagonal)

Backlight: Blue (On for 3 minute unless turned off manually)

Mini-USB Port: For updating to latest version of firmware.

Battery: 6 x AA (Battery life below based on alkaline type)

Battery life: 350 hours (without backlight)

Low battery indication:

is displayed when the battery

voltage drops below the operating level

Auto Shut off: 30 minutes of inactivity when APO is activated

Operating environment: 32°F to 122°F (0°C to 50°C) at <75%

relative humidity

Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH

(with battery removed)

Temperature coefficient: 0.1 x (specified accuracy) per °C (0°C to

18°C, 28°C to 50°C), per 0.6°F (32°F to 64°F, 82°F to 122°F)

Over range: "OL" or "-OL" is displayed

Weight: 3.04 lbs (1.38 kg)

Pressure

Connector Type: Standard 1/4" NPT male flare fitting

Range: 29” HgV to 580 Psig (English), 74 cmHgV to 0 to 4000KPa

(Metric)

Resolution: 0.1 psi/inHg; 1 kPa/cmHg

Accuracy: 29” HgV to 0” HgV: ±0.2” HgV

74 cmHgV to 0 cmHgV: ±1 cmHgV

0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa:

±0.007MPa; 0 to 13.78 bar ±0.07 bar

200 to 580 Psig: ±(0.3% of reading+1 Psig); 1378 to 4000KPa: ±(0.3% of

reading+7 Kpa); 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa);

13.78 to 40.00bar: ±(0.3% of reading +0.07bar)

Maximum overload pressure: 800 psig

Units: Psig, kPa, MPa, bar, inHg, and cmHg

Temperature

Sensor type: Type K thermocouple

Range: -95°F to 999.9°F (-70°C to 537.0°C)

Resolution: 0.1°F/°C

Accuracy: ±(1.0°F) -95°F to 199.9°F; ±(0.5°C) -70°C to 93°C

±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C

Note: All accuracies are after a field calibration.

Maintenance

Clean the exterior with a dry cloth. Do not

use liquid.

Battery Replacement

The battery must be replaced when the

battery life indicator

is empty. SMAN will

display "lo batt" and power off. Remove rear

battery cover and replace with 6 AA batteries.

Auto Power Off (APO)

To conserve battery life, your SMAN will

power down after 30 minutes of inactivity. APO

is activated by default and APO displays above

the battery icon. To deactivate, press and hold

ENTER while powering on the SMAN. When

deactivated, APO will no longer show above

the battery icon.

LOW

HIGH

Pressure (bar)

Pressure (pounds/in

2

)

Pressure (kilopascals or Megapascals)

Negative Pressure (inches of mercury)

Negative Pressure (cm of mercury)

Suction Line Temperature

Liquid Line Temperature

Vapor Saturation Temperature

Liquid Saturation Temperature

Superheat

Subcooling

Target Superheat

Static Target Superheat Calculation

Outdoor Dry Bulb

Indoor Wet Bulb

Battery Life

Auto Power Off Enabled

Selected Refrigerant of System

13

11

12

1

1

2

2

3

4

5

8

9

10

6

7

LOW

HIGH

Advertising